ED630-0300-PA-G-000
- Υποστηρίζουν πρωτόκολλα επικοινωνίας:RS-232,RS-485,CAN BUS, PROFIBUS DP.
- Τάση Τροφοδοσίας: Τριφασική AC380V±15%
- Ονομαστική Ισχύς(KW):1.2-4.0
- Διαστάσεις σε mm : 300X166X115.5 300X166X125.5
Please select an option
Description
Model | ED620/ED630 | |||||
ED620-0120-XA-G-000 | ED620-0150-XA-G-000 | ED620-0180-XA-G-000 | ED630-0250-XA-G-000 | ED630-0300-XA-G-000 | ED630-0400-XA-G-000 | |
Main Supply Voltage | 3-Phase AC380V±15% | |||||
Rated Power Frequency | 50Hz-60Hz | |||||
Control Power Supply | DC24±10%,2A | |||||
Digital Signal Input | DC24±10%,10mA | |||||
Digital Signal Output | DC24±10%,0.5A | |||||
Analog Signal Snput | -10V~+10V | |||||
Rated Output Power(KW) | 1.2 | 1.5 | 1.8 | 2.5 | 3 | 4 |
Energy-Consumed Braking | If the system generates an Over-Voltage alarm when it starts or stops sharply, add an external braking resistor to absorb the feedback energy of the motorW | |||||
Energy-Consumed Braking Voltage | DC670±5V | |||||
Over-Voltage Alarm Voltage | DC710±5V | |||||
Under-Voltage Alarm Voltage | DC410±5V | |||||
Dimensions mm (H×W×D) | 300X166X115.5 | 300X166X125.5 | ||||
Weight | 4.6 | 4.5 | ||||
Operating Temperature | 0~40℃ | |||||
Storage Temperature | -10~70℃ | |||||
Humidity | 5~85% | |||||
Contamination Level | 2 | |||||
Protection Level | IP20 | |||||
Installation Environment | Installed in a Dust-Free, Dry, and Lockable Environment (in a Electrical Cabinet, for Example) | |||||
Installation Mode | Vertical Installation | |||||
Installation Altitude | No Power Limit Under 1000m | |||||
Pressure | 86~106kpa | |||||
Internal Programmable | An Internal Space of 16.5 KB is Provided for 256 Sequences, Which can Save a Controller on some Occasions | |||||
External I/O | 3 External Digital Outputs (24V,0.5A),the Target Position to Output or Alarm Output Function can be Implemented by Internal Programming; | |||||
8 External Digital Inputs, Supporting Internal Sequence Calling Via the Input Interface and Positioning Function | ||||||
(input delay: about 1 ms; input current: about 4 mA) | ||||||
Analog Input | ne Differential Analog Input, Implementing Control over Motor Speed and Position by Analog Input; Input Voltage Range ± 10V, Input Delay: About 0.1 ms | |||||
Analog Output | Two Independent Analog Outputs, Capable of Monitoring the Change of Internal Objects | |||||
Comparator | Four Internal Comparators, with the Comparison Results to be Used to Trigger Program Sequences | |||||
Timer | Supporting the Function of Triggering Sequences by Timer or Events | |||||
Counter | Four Groups of Internal Counters, Which can be Set to Trigger Sequences | |||||
Calculator | An Internal Calculator can be Used for Data Duplication, Addition, Subtraction, Multiplication, and Division, and Logic Operation | |||||
Internal Oscilloscope | The ECO2WIN Software Enables a User to Monitor Operation Parameters Such as Speed, Position and Current on a PC | |||||
Encoder Signal Output Function | In a Master/Slave Control Mode, the Motor Encoder Signal or Master Encoder Signal can be the Input for the Slave Signal Encoder, with a Maximum Output Frequency of 2 MHz | |||||
Master Encoder Signal Input Function | Programmable to be Pulse/Direction Signal Control, CW/CCWW Control, Electronic gear or Electronic Cam Control (5V Signal), with a Maximum Output Frequency of 2 MHz | |||||
Feedback Signal | Incremental A, B, Z , /A, /B, /Z signal | |||||
RS232 | 9.6K Baud Rate, Supporting a Maximum of 15 Sites, and Supporting Direct Communication with a PC with the ECO2WIN Software, or Direct Communication with an eView Touch Screen or Text | |||||
RS485 | 38.4K Baud Rate, Supporting a Maximum of 15 Sites, and Communication Cables with a Length up to 400M | |||||
CAN BUS | Maximum Baud Rate of 1M, and Supporting a Maximum of 127 Sites | |||||
PROFIBUS DP | Maximum Baud Rate of 12M, and Supporting a Maximum of 127 Sites |
Επικοινωνία
RS232+Profibus
Ονομαστικό Φορτίο
3KW