DRA-40-24

PDFPrintEmail

  • Universal AC input / Full range

  • Protections: Short Circuit / Overload / Over Voltage

  • Can Be Installed on DIN rail TS-35/7.5 or 15

  • Output Voltage Adjustable Through Internal Potentiometer

  • Output Current Adjustable Through External 1~10Vdc, PWM Signal Or Resistance

  • Cooling By Free Air Convection

  • Pass LPS

  • LED Indicator For Power On

  • 100% Full Load Burn-In Test

  • 3 Years Warranty

DRA-40-24
Sales price without tax 27,50 €
Τιμή / kg:
Description
SPECIFICATION
MODEL  DRA-40-24
OUTPUT DC VOLTAGE 24V
CONSTANT CURRENT REGION 3~24V
RATED CURRENT 1.7A
CURRENT RANGE 0 ~ 1.7A
RATED POWER 40.8W
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE 24 ~ 30V
VOLTAGE TOLERANCE Note.3 ±1.0%
LINE REGULATION ±0.5%
LOAD REGULATION ±0.5%
SETUP, RISE TIME Note.4 400ms, 90ms/230VAC 800ms, 90ms/115VAC At Full Load
HOLD UP TIME (Typ.) 50ms/230VAC 10ms/115VAC At Full Load
INPUT VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC [DC Input Operation Possible By Connecting AC/L(+), AC/N(-)]
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 87%
AC CURRENT (Typ.) 0.8A/115VAC 0.6A/230VAC
INRUSH CURRENT (Typ.) COLD START 30A/115VAC 60A/230VAC
PROTECTION OVERLOAD 95 ~ 108% Rated Output Power
Protection Type : Constant Current Limiting, Recovers Automatically After Fault Condition Is Removed
OVER VOLTAGE 28.98 ~ 37.26V
Protection Type : Shut Down o/p Voltage, Re-Power On To Recover
ENVIRONMENT WORKING TEMP. -30 ~ +70°C (Refer To "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH Non-Condensing
STORAGE TEMP., HUMIDITY -40 ~ +85°C, 10 ~ 95% RH°C
TEMP. COEFFICIENT ± 0.03%/°C (0 ~ 55°C) On Output
VIBRATION 10 ~ 500Hz, 2G 10Min./1Cycle, 60min. Each Along X, Y, Z Axes
SAFETY &EMC(Note 5) SAFETY STANDARDS UL60950-1, TUV EN60950-1 Approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
EMC EMISSION Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61204-3, Light Industry Level, Criteria A
OTHERS MTBF 439.3K Hrs Min. MIL-HDBK-217F (25°C)
DIMENSION 40*90*100mm (W*H*D)
PACKING 0.3Kg; 42pcs/13.6Kg/0.82CUFT
NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.

5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on http://www.meanwell.com)

6. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.

 

DRA-40-24 Specification