MDR-100-24

PDFPrintEmail

  • Universal AC input / Full range

  • Protections: Short circuit / Overload / Over voltage / Over temperature

  • ZCS/ZVS technology to reduce power dissipation

  • Cooling by free air convection

  • Can be installed on DIN rail TS-35/7.5 or 15

  • DC OK relay contact

  • No load power consumption<1W

  • LED indicator for power on

  • 100% full load burn-in test

  • 3 years warranty

MDR-100-24
Sales price without tax 43,65 €
Τιμή / kg:
Description
SPECIFICATION
MODEL MDR-100-24
OUTPUT DC VOLTAGE 24V
RATED CURRENT 4A
CURRENT RANGE 0 ~ 4A
RATED POWER 96W
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE 24 ~ 30V
VOLTAGE TOLERANCE Note.3 ±1.0%
LINE REGULATION ±1.0%
LOAD REGULATION ±1.0%
SETUP, RISE TIME Note.5

3000ms, 50ms/230VAC

3000ms, 50ms/115VAC at full load

HOLD UP TIME (Typ.)

50ms/230VAC

20ms/115VAC at full load

INPUT VOLTAGE RANGE

85 ~ 264VAC

120 ~ 370VDC

FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.)

PF≧0.95/230VAC

PF≧0.98/115VAC at full load

EFFICIENCY (Typ.) 86%
AC CURRENT (Typ.)

1.3A/115VAC

0.8A/230VAC

INRUSH CURRENT (Typ.)

COLD START 30A/115VAC

60A/230VAC

LEAKAGE CURRENT <1mA / 240VAC
PROTECTION OVERLOAD 105 ~ 150% rated output power
Protection type :Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 31.2 ~ 36V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, auto-recovery or re-power on to recover
FUNCTION DC OK SIGNAL Relay contact rating(max.): 30V/1A resistive
ENVIRONMENT WORKING TEMP. -10 ~ +60°C (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85°C, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/°C (0 ~ 50°C)
VIBRATION Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6
SAFETY &EMC (Note 4) SAFETY STANDARDS UL508, TUV EN62368-1, BSMI CNS14336-1EAC TP TC 004, AS/NZS 60950.1 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25°C/ 70% RH
EMC EMISSION Compliance to EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3,Class BEAC TP TC 020, CNS13438
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A, EAC TP TC 020
OTHERS MTBF 346K hrs min. MIL-HDBK-217F (25°C)
DIMENSION 55*90*100mm (W*H*D)
PACKING 0.42Kg; 30pcs/13.6Kg/0.82CUFT
NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on http://www.meanwell.com)

5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

6. Deating maybe needed under low input voltages, please check the derating curve for more detail.

7. The ambient temperature derating of 3.5°C /1000m with fanless models and of 5°C /1000m with fan models for operating altitude higher than 2000m (6500ft).

Product Liability Disclaimer For detailed information, please refer tohttps://www.meanwell.com/serviceDisclaimer.aspx


MDR-100-24 Specification